R-1 — Single-Family Residential

Minimum lot area 10,000 square feet. Minimum width at the setback line is 80 feet for single-family/duplex, 40 feet for single-family semi-detached, and 120 feet for single-family attached/multi-family (3+ units) (Table 4.1.3.B, footnote 1). Maximum impervious surface coverage 60 percent; the calculation method is set out in LDC Article 1, Sec. 1.15.M.

RML — Residential Multi-Family Low

Minimum lot area 10,000 square feet. Maximum impervious surface coverage 60 percent. Minimum width at setback line follows the same footnote as R-1: 80 feet single-family/duplex, 40 feet semi-detached, 120 feet attached/multi-family (Table 4.1.3.B, footnote 1).

RMM — Residential Multi-Family Medium

Minimum lot area 43,560 square feet (1 acre). No maximum impervious surface cap listed in Table 4.1.3.B (shown as 'None').

RE — Residential Estate

Minimum lot area 40,000 square feet. No maximum impervious surface cap listed (shown as 'None').

A — Agricultural

No minimum lot area listed for residential use (shown as 'None'); non-residential uses in the A district require a minimum of 4 acres per Table 4.1.3.B footnote 4 (Sec. 4.2.5.C separately states 5 acres for non-residential uses; confirm which figure controls before acting, this is a genuine inconsistency between the table footnote and the district text). No maximum impervious surface cap is listed.

C — Commercial

No minimum lot area listed (shown as 'None'). Maximum floor area ratio (FAR) 1.

P — Professional Office

No minimum lot area listed (shown as 'None'). Maximum floor area ratio (FAR) 1.

I — Industrial

No minimum lot area listed (shown as 'None'). Maximum floor area ratio (FAR) 1.

INST — Institutional

No minimum lot area listed (shown as 'None'). Maximum floor area ratio (FAR) 1.

PV — Preservation

No minimum lot area listed (shown as 'None'). No FAR listed (shown as 'None').

CC — Commercial Corridor

No minimum lot area listed for the district generally (shown as 'None'), except single-family attached and multi-family dwellings need a minimum of 4 acres (Table 4.1.3.B). Maximum floor area ratio (FAR) 1.25. Residential density is separately capped at a minimum of 10 or 50 units and a maximum of 25 units/acre (Table 4.1.3.A).

NC — Neighborhood Commercial

No minimum lot area is set; instead, Table 4.2.12 varies allowable use-area mix and density by total development project size. For developments of 1 acre or less: free-standing commercial may be 0-100% of the site (FAR 1.0); free-standing residential is not allowed (N/A); mixed-use may be 0-100% of the site (density 3-12 d.u./acre, FAR 1.0). For developments 1 to 19.99 acres: free-standing commercial 15%-100% of site; free-standing residential 15%-85% of site (12 d.u./acre or 50 units minimum, 16 d.u./acre maximum); mixed-use 0-100% of site (12 d.u./acre or 50 units minimum, 16 d.u./acre maximum, FAR 2.0). For developments 20 acres or greater: free-standing commercial 20%-75% of site; free-standing residential 25%-80% of site (12 d.u./acre or 75 units minimum, 16 d.u./acre maximum); mixed-use 0-100% of site (12 d.u./acre or 75 units minimum, 16 d.u./acre maximum, FAR 2.0). Table 4.1.3.A separately states a citywide NC density ceiling of 12 or 50 units minimum (75 units above 20 acres) to 16 d.u./acre maximum, consistent with these figures.

MX7 — Mixed-Use Seven Islands

No minimum lot area listed (shown as 'None'). Maximum floor area ratio (FAR) 1. Residential density is separately capped at a maximum of 995 units total (a fixed unit cap, not a per-acre density, per Table 4.1.3.A).

MXB — Mixed-Use Bimini

No minimum lot area listed generally (shown as 'None'), except single-family attached and multi-family dwellings need a minimum of 4 acres (Table 4.1.3.B). Maximum floor area ratio (FAR) 4. Residential density is separately capped at a maximum of 125 units/acre (Table 4.1.3.A).

SC — South Cape

No minimum lot area listed (shown as 'None'). Maximum floor area ratio (FAR) 4. Table 4.2.15 separately caps density at 125 d.u./acre (matching the citywide Table 4.1.3.A figure).

PUD — Planned Unit Development

Dimensional standards for a PUD are set in the adopting ordinance and master concept plan, not in the citywide dimensional table (Sec. 3.4.7). Check the specific PUD ordinance for the parcel.